| COGNEX Partner System Integrator - 成都新西旺自动化科技有限公司

Industry Information

Understand troubleshooting methods for machine vision industrial cameras

Publishing Date:2022-11-23 09:12:15    Views:

Industrial cameras are a key component in machine vision systems, and their essential function is to convert optical signals into ordered electrical signals. Choosing the right camera is very important in the design of machine vision system, the choice of camera directly determines the resolution and image quality of the captured image, and is also directly related to the operation mode of the entire system. Let's understand the solution to the failure of industrial cameras together!

 

1. Open the detection program and prompt that the camera cannot be found

 

Troubleshooting method:

 

(1) Check whether the camera power supply is connected and whether the camera network cable is damaged.

 

(2) Check the NIC driver and camera driver.

 

(3) Check the network adapter parameters, camera and computer IP.

 

2. The camera is offline and the image is black during use

 

Troubleshooting method:

 

(1) The camera power adapter, the network cable used by the camera and the computer to transmit data is special for industry, and the use of non-supporting hardware will cause the connection of the camera to fail, the camera is offline during use, the image is black during normal use, the camera is hot and other problems.

 

(2) Network adapter parameters and camera bandwidth must be configured correctly (they have been configured before delivery).

 

(3) The power cable of the camera and the network cable of the camera are properly secured.

 

(4) Replace the camera cable and check whether the cable is unstable or damaged.

 

3. The camera cannot be found after power off or forced shutdown and restart the computer

 

Troubleshooting method:

 

(1) Try to disable the network card from the device manager, unplug the camera power plug-in and power it up after two minutes, and then restart the computer

 

(2) The camera power adapter, the network cable used by the camera and the computer to transmit data is special for industry, and the use of non-supporting hardware will cause the connection of the camera to fail and the camera to drop offline during use.


Contact Us

Phone:028-62705808

Fax:028-62705808

Mobile Phone:18215640190

Email:sales@cdxiwang.com

Address:2-8-6, Chen Electric Technology Innovation Park, 68 Shuangbai Road, High-tech West District, Chengdu

Baidu
map