| COGNEX Partner System Integrator - 成都新西旺自动化科技有限公司

Industry Information

Briefly describe the solutions to common failures of industrial cameras and industrial lenses.

Publishing Date:2020-04-20 10:51:44    Views:

         

 Industrial cameras and industrial lenses are key components in machine vision systems. Their most essential function is to convert optical signals into ordered electrical signals. Selecting the appropriate camera and lens is also an important link in the design of the machine vision system. It not only directly determines the resolution and image quality of the collected images, but is also directly related to the operating mode of the entire system. Let’s learn about the solutions to common failures of industrial cameras and industrial lenses:

1. When opening the detection program, it prompts that the industrial camera cannot be found?

Troubleshooting method:

⑴ Check whether the camera power supply is connected and whether the camera network cable is damaged. (Common malfunctions)

⑵ Check the network card driver and camera driver.

⑶ Check the network card parameters, camera and computer IP. (Common malfunctions)

2. The industrial camera goes offline and the image goes black during use?

Troubleshooting method:

⑴The camera power adapter and the network cable used to transmit data between the camera and the computer are industrial-specific. The use of non-matching hardware will cause problems such as failure to connect to the camera, camera disconnection during use, black screen image during normal use, and serious camera heating.

⑵The network card parameters and camera bandwidth must be configured correctly (already configured at the factory).

⑶ Whether the camera power cord and camera network cable are tightened properly.

⑷Replace the camera network cable and check whether the network cable is unstable or damaged.

3. Dual (multiple) cameras After restarting the computer, one camera cannot be found.

Troubleshooting method:

⑴Try to disable the network card from the device manager, unplug the camera power plug, power it off again after two minutes, and then restart the computer.

⑵The camera power adapter and the network cable used to transmit data between the camera and the computer are industrial-specific. Using non-matching hardware will cause failure to connect to the camera and cause the camera to disconnect during use.

4. There was a power outage or forced shutdown during use, and the camera could not be found after restarting.

Troubleshooting method: Same as question 3.

Industrial lens failure

1. Does the image become blurry during use?

Troubleshooting method:

⑴The small screw that locks the focal length on the lens is not tightened, and the vibration of the machine operation causes the focal length of the lens to shift.

⑵The connection between the lens and the camera is unreliable. Reinforce the connection.